CLI

CLI quick reference

The gridsim command line tool, verb by verb. Every verb answers gridsim <verb> --help with its usage, flags, defaults and exit codes. The full chapter is CLI reference on the site.

Verb index

Group Verbs
Software licence licence
Help help (and gridsim <verb> --help)
Running a case no verb
Contingency and analysis trip, screen, nminus1, nminus2, n-1-1, nminus1-sweep, stress, chain, cycle, corrective-sequence
Network analysis pf, ptdf, lodf, sensitivity, qv-curve, pv-contingency, dc-contingency, fault-level-n1, line-constants, dist3ph-mesh, substation-state, cgmes-export, cgmes-conform, dgs-import, dcpf, dcopf, acopf, acopf-full, scuc, scopf, transmission-security, transfer-capability, cgmes-study, planning-study, study-case, case-diff, result-diff, report, restoration-study, reliability-study, reliability-network, probabilistic, qsts, hosting, cpf, taps, restore, losses, dist3ph (experimental)
Physics and protection physics-check, conformance, protection-check, grade, devices-check, fault-line, sc-trace, protection-audit, fault, fault-series, fault-simultaneous, iec60909, g74, arc-flash, cable-rating, experimental
Frequency and dynamics freq, replay, transient, domains, stability, modal, modal-full, fit-frequency, inertia-placement, dynamics-study, motor-start, user-model
Harmonics, impedance and EMT harmonics, harmonic-assess, flicker, filter-design, impedance-stability, emt, emt-line, emt3
Evidence replay-event, scenario, h0-study, fleet, evidence
Data gda, gda-replay, synth, export, convert, validate, zonal, pmu-ingest (experimental), pmu-estimate, estimate, estimate-noise-floor, crossval
Real-time and telemetry serve, rpc, interpose
Benchmarking and preflight bench, bench --estimate, bench --perf, gpucheck, simdcheck, batchsolve, audit, compliance
Electrical references ref

All verbs (117)

Verb Summary Full section
licence Inspect and install the software licence (ch. 4). licence
help With a verb, prints that verb's section of this chapter as plain text: its usage line, every flag with its default, its exit codes and the notes its group shares, then the general exit-code rule, and exits 0. help
no verb Solve a case without naming a verb, for example gridsim case14 --once; a built-in case name, a MATPOWER file or --dir <path>. Running a case (no verb)
trip Trip a generator and report the peak RoCoF (Peak RoCoF, the largest |df/dt| over the run), the nadir and the settling frequency, plus the same trip at half inertia. trip
screen N-1 RoCoF screening: rank every credible single infeed loss against the GB limits (RoCoF 0.125 Hz/s, statutory 49.5 Hz, LFDD risk) and report the binding case's inertia floor and headroom. screen
nminus1 Sequential N-1 branch outage screening on one model: each branch out in turn, re-solved, classified secure / violations / islanded. nminus1
nminus2 N-2 branch screening: two elements lost at once. nminus2
n-1-1 N-1-1 sequential screening: lose one element, let the operator take corrective action, then lose a second element from that corrected state. n-1-1
nminus1-sweep Parallel N-1 branch sweep with throughput reporting, over one case or the whole case registry (--all is the embedded classics plus every .m under data/matpower/). nminus1-sweep
stress Load-to-collapse: scale the operating point until the flow stops converging and report max loadability. stress
chain Consecutive warm-started solves: each step feeds the previous solution in as the initial condition. chain
cycle The real-time prioritised parallel analysis cycle: one single-core Newton-Raphson base solve per cycle, then a worker-pool fan-out of every downstream analysis (N-1 sweep, harmonics, RoCoF screening, physics conformance and the watch... cycle
corrective-sequence Ordered corrective N-1-1 study (RC3). corrective-sequence
pf One AC power flow on the engine the shared rule picks (radial sweep, dense or sparse Newton), 100 iterations with reactive limits on, printed: convergence, iterations, mismatch, losses, the voltage range and the --top lowest bus voltages. pf
ptdf Power transfer distribution factors: +1 MW injected at --bus and withdrawn at the slack, and the share that flows on each branch, largest first (factors below 1e-4 are not listed). ptdf
lodf Line-outage distribution factors: how the flow of the outaged branch redistributes onto the others, largest first. lodf
sensitivity First-order sensitivities of a case. sensitivity
qv-curve The QV curve of one bus: the reactive power a synthetic voltage-controlling unit at the bus must supply to hold each voltage. qv-curve
pv-contingency Maximum loadability (the nose of the PV curve) under each single-branch outage: the cpf walk (load multiplier stepped up and bisected, every point solved with the contingency study solver and options) run on the base case and on the... pv-contingency
dc-contingency DC N-1 screen: one factorisation of B', the base DC flows (in-service generation minus demand, each DC island's reference absorbing its imbalance, as dcpf), then for each outage flow_after = flow_before + LODF flow_outaged in MW. dc-contingency
fault-level-n1 Three-phase fault level under N-1: for the intact network and then each single-branch outage in index order, the outage copy is built and the IEC 60909 initial symmetrical current Ik'' is evaluated at every bus (or the --buses list). fault-level-n1
line-constants Overhead line constants from conductor geometry (Core GridSim.Core.Lines): the series impedance and potential coefficient matrices of the cross-section, reduced to what a power-flow or fault study needs. line-constants
dist3ph-mesh Meshed, unbalanced load flow in the explicit phase frame (Core GridSim.Core.Distribution.Meshed). dist3ph-mesh
substation-state Node-breaker topology processing (RC4 R4-11 part A, Core GridSim.Core.Model.Substations). substation-state
cgmes-export CGMES per-profile export of a native node-breaker file (RC4 R4-11 part B; Core GridSim.Core.IO.Cim.Profiles). cgmes-export
cgmes-conform Checks a CGMES bundle against GridSim's own, hand-coded subset of the published profile rules (RC4 R4-11 part B). cgmes-conform
dgs-import Imports an ASCII PowerFactory DGS file (RC4 R4-11 part C, Core GridSim.Core.IO.Dgs) through the node-breaker model of substation-state: every DGS terminal is a connectivity node, every coupler and cubicle switch is a switch, and the... dgs-import
dcpf DC power flow: bus angles and branch flows from the linearised network, through the same DC model the PTDF, LODF and DC-OPF use (DistributionFactors; Core DcPowerFlow). dcpf
dcopf DC optimal power flow: the cheapest dispatch that meets demand, with line limits enforced unless --no-limits. dcopf
acopf DC dispatch with an AC loss loop (AcOptimalPowerFlow): NOT a full AC optimal power flow. acopf
acopf-full The full AC optimal power flow (AcOpfInteriorPoint): a primal-dual interior point method, MATPOWER's MIPS with its defaults, starting point and stopping conditions. acopf-full
scuc Security-constrained unit commitment (UnitCommitment): which units run in each period, and at what output, at least total cost. scuc
scopf Preventive security-constrained DC optimal power flow (DcScopf): the cheapest dispatch that keeps every rated branch within RATE_A in the intact network and within its post-outage rating after each secured single-branch outage, with... scopf
transmission-security Preventive branch N-1 study with AC verification (RC3). transmission-security
transfer-capability AC-verified directional transfer capability (RC3). transfer-capability
cgmes-study CGMES as a normal study job (RC3). cgmes-study
planning-study Versioned planning snapshots and repeatable studies (RC3). planning-study
study-case Study cases (RC4 R4-01): one immutable master case, dated variations, named operation scenarios, grouping objects and studies, expanded deterministically and run as one ordered batch. study-case
case-diff Read-only comparison of the authored JSON files of two native cases (RC4 R4-01): a v1 case folder, or a v2 case manifest with its network and asset files. case-diff
result-diff Read-only comparison of two result documents (RC4 R4-01), member by member in document order. result-diff
report Report generator of the workbench (RC4 R4-10). report
restoration-study Restoration switching-sequence study (RC3 P8). restoration-study
reliability-study Analytical radial-feeder reliability study (RC3 P8). reliability-study
reliability-network Reliability and restoration joined on the real network (RC4 R4-13). reliability-network
probabilistic Probabilistic load flow and generation adequacy (RC4 R4-09), with the sampling method a request field: plain Monte Carlo (monte-carlo), quasi-Monte Carlo (qmc, unscrambled Sobol; qmc-shifted, with an independent random digital... probabilistic
qsts Quasi-static time series (QstsEngine): a sequence of power flows, one per step, over the load, generation, PV and storage profiles of a study file, warm-started from the previous step, with the controllers acting in time and their... qsts
hosting Hosting capacity (HostingCapacity): the largest PV (or, with --resource load, added demand such as electric vehicle charging or heat pumps) at each candidate bus before a limit is broken, found by bisection on the size in MW. hosting
cpf Maximum loadability by stepping and bisection (ContinuationPowerFlow.MaxLoadability). cpf
taps Coordinated tap schedule (TapOptimizer.Flatten): one set of tap ratios across every OLTC that minimises the sum of squared bus-voltage deviations from --target, rounded to each OLTC's step grid. taps
restore Restoration (black-start) sequence check (RestorationSequencer.Evaluate). restore
losses Loss allocation on the solved base case, under a header naming the case (Loss allocation - <case> (N buses, M branches)): total P and Q losses, the real power drawn by bus shunt conductances (Bus shunt conductance, only when the... losses
dist3ph EXPERIMENTAL. The unbalanced three-phase distribution stack (GridSim.Core.Distribution) on a radial feeder read from a gridsim-dist3ph/1 JSON file, or (N339, October 2026) its JSON v2 form gridsim-dist3ph/2 (format in technical... dist3ph
physics-check Audit one solved state against the physical laws (energy balance, Ohm, Joule, KCL, complex power, and the rest of the registry) and print one row per law. physics-check
conformance Run the physics-law audit over the whole case registry (embedded classics plus every .m under data/matpower/) and write conformance.md, conformance.csv and run-metadata.json. conformance
protection-check Passive protection assessment of the solved state with generic relay settings: which elements would operate, with pickup, time and basis. protection-check
grade Inverse-time overcurrent grading (OvercurrentCoordination.GradeChain): a radial chain of relays, listed downstream first, graded pair by pair (primary then its backup) at each fault current. grade
devices-check Validate a placed-device file and bind it to a case (RC4 R4-07, Core GridSim.Core.Protection.Devices). devices-check
fault-line Three-phase fault along a line (RC4 R4-07). fault-line
sc-trace Short-circuit trace for one fault (RC4 R4-07): the current each placed device measures through its CT, its operating time, its confidence (Grounded for a tabulated manufacturer curve, Generic for an equation on a user setting,... sc-trace
protection-audit Coordination audit of a placed-device set (RC4 R4-07). protection-audit
fault Balanced three-phase fault at --bus through fault reactance --zf (pu, Zf = j--zf, printed Zf=j...; D-DOC-166: dist3ph fault --zf is a resistance instead): fault current (pu, and kA when the bus has a base kV), Thevenin... fault
fault-series Open-conductor (series) fault in the series element of one branch: one conductor open (--open 1, phase a) or two open (--open 2, phases b and c). fault-series
fault-simultaneous Solid shunt faults at several buses at the same instant (a cross-country fault, or one fault with a second developing at another bus), on the operating point and the same sequence networks as fault --type. fault-simultaneous
iec60909 IEC 60909 short-circuit duty at --bus (Iec60909): initial symmetrical current Ik'', peak ip with its factor kappa and the fault-loop R/X, breaking Ib, steady Ik, thermal-equivalent Ith over --tk with its factor m, the DC component... iec60909
g74 A G74-style short-circuit duty built over the IEC 60909 machinery (RC4 R4-06; Protection/ShortCircuit/Ena). g74
arc-flash Incident energy and arc-flash boundary of one piece of equipment to IEEE 1584-2018 (RC3 P8): equations 1 to 25 with the coefficients of Tables 1 to 7, three-phase AC only. arc-flash
cable-rating Steady-state current rating of one single-core unarmoured cable laid direct in the ground, isolated from other cables (RC3 P8): IEC 60287-1-1 (rating equation with n = 1, T2 = 0 and lambda2 = 0; AC resistance with the skin effect for xs... cable-rating
experimental Opt-in experimental models, tagged unvalidated-at-scale and kept off the validated solve and estimate paths. experimental
freq NESO 1-second frequency statistics plus a GB limit-breach scan (RoCoF 0.125 Hz/s, operational 49.8 Hz, statutory 49.5 Hz, LFDD 48.8 Hz) and a 20 ms upsample demo. freq
replay Play a recorded frequency trace in the terminal (gauge and RoCoF), upsampled to 20 ms. replay
transient Headless demanding time-domain run: a simulated duration at a fine slice, integrating swing-equation frequency each slice. transient
domains Report the speed domains of the distributed-inertia model: per-domain machine count, GVA.s and GVAd stiffness, and whether a dominant domain exists (deltaGVA at least 10 %). domains
stability Classical multi-machine transient stability (constant E' behind X'd, Kron-reduced network, RK4 swing). stability
modal Small-signal (modal) stability of the linearised multi-machine swing: eigenvalues, frequency and damping ratio of every mode, the least-damped oscillatory mode, right-half-plane count, the dominant participating states per mode and an... modal
modal-full Full-model small-signal (modal) analysis (RC4 R4-12; GridSim.Core.Dynamics.SmallSignal.Full). modal-full
fit-frequency Fit the lumped swing model's nadir and recovery constants to one measured loss-of-infeed trace (R079, October 2026): load self-damping (DampingPctPerHz, % of demand per Hz), the responsive headroom fraction and the governor time... fit-frequency
inertia-placement The inertia placement study: with a network's synchronous inertia in better places, can it run on less of it? inertia-placement
dynamics-study Native RMS dynamics study over a PSS/E RAW case and its DYR file (RC3 P6). dynamics-study
motor-start Motor acceleration study from a native JSON operating point (RC3 P8). motor-start
user-model Declarative dynamic models (RC4 R4-08, Core GridSim.Core.Dynamics.UserModels). user-model
harmonics Frequency-domain harmonic study on the study model (network, machine source impedance, loads as damping shunts): penetration (Y(h) V = I), the driving-point resonance scan, a fine frequency sweep for the true peak between integer... harmonics
harmonic-assess UK harmonic connection assessment by the staged procedure of ENA Engineering Recommendation G5 Issue 5 (2020; docs/reference S139; the ENA publishes it free of charge), RC4 R4-21. harmonic-assess
flicker UK flicker and rapid-voltage-change assessment by ENA Engineering Recommendation P28 Issue 2 (2019; docs/reference S141; free), and the structure of the IEC 61000-4-15 flickermeter (RC4 R4-21). flicker
filter-design Passive harmonic filter design by closed forms (RC4 R4-21): single-tuned, high-pass (second-order damped) and C-type. filter-design
impedance-stability Impedance-based (generalised Nyquist) inverter-grid stability screen: forms the loop gain of the grid impedance and the converter admittance over frequency (SISO: the positive- and negative-sequence loops in the converter's dq frame,... impedance-stability
emt Electromagnetic-transient time-domain solve: a Dommel nodal companion-model engine steps the instantaneous network at a fixed microsecond timestep. emt
emt-line Lossy travelling-wave line impulse study (RC3 P8). emt-line
emt3 Three-phase electromagnetic transients on the RC4 nodal solver (Core GridSim.Core.Dynamics.Emt.Nodal, Nonlinear and FrequencyDependent), in SI units with a fixed step and the trapezoidal rule. emt3
replay-event The credibility gate: reproduce a recorded event's RoCoF and nadir with no device. replay-event
scenario The counterfactual sweep (inertia x device x corners) plus the inertia risk curve. scenario
h0-study The H=0 counterfactual: scale the real synchronous inertia toward zero while making a growing fraction of the converter fleet grid-forming, per asset (fleet-routed). h0-study
fleet Single-versus-fleet emergent behaviour: the same total device budget split across N staggered units. fleet
evidence The umbrella dossier (gridsim-evidence/1): recorded versus simulated versus counterfactual columns, risk curve, fleet comparison and avoided cost. evidence
gda Read the read-only GDA data lake and materialise a GridSim replica (data stays out of the repo). gda
gda-replay The historical state estimator: replay a demand time series through the validated solver, reconstructing grid state at each past timestamp (horizon-guarded, never nowcasting). gda-replay
synth Build the synthetic GB-at-scale case (no data held under a licence), solve it, and materialise it as a JSON case directory. synth
export Write a visualisation scene (buses, branches, animation frames) for external renderers. export
convert Convert a case between MATPOWER, PSS/E RAW, CGMES, a JSON case folder (v1) and a JSON v2 case. convert
validate Check GridSim JSON v2 documents with the Phase 1 validator, choosing the check by each document's "schema" tag: gridsim-case/2 against case.schema.json (and, when the manifest is valid, each network file it lists, read relative to... validate
zonal Show a PyPSA-GB zonal transport model: the bundled pypsa-gb-zonal (PyPSA-GB @ 8e084af, MIT, 20 zones and 37 links, under data/matpower/gb/pypsa-gb/zonal) or a folder holding the same two files, buses.csv (name,y,x,v_nom,carrier:... zonal
pmu-ingest EXPERIMENTAL. Decode a recorded IEEE C37.118.2 synchrophasor stream: the frames as sent, back to back, a CONFIG-1 or CONFIG-2 frame followed by DATA frames (technical ch. 33). pmu-ingest
pmu-estimate The linear PMU state estimate (1.95.245). pmu-estimate
estimate The measurement-based WLS state estimator. estimate
estimate-noise-floor The measurement noise-floor study. estimate-noise-floor
crossval An existing solve-export.json is diffed as it is: one written by another verb at the everyday 1e-8 pu carries that solve's own residual and will not agree to machine epsilon for that reason alone (the sidecar says so when its final... crossval
serve Run the real-time estimator as a resident stream over a directory of gridsim-measurements/1 files, taken in file-name order. serve
rpc The in-process access endpoint the Python package drives (gridsim.Session, see Python): a resident request and response service, gridsim-rpc/1, that holds loaded cases between requests. rpc
interpose The RTU/SCADA interposer: receive live protocol frames, validate and correct each frame, decode it to typed points, map the points through the crosswalk, and emit gridsim-measurements/1 windows. interpose
bench The solver x backend matrix over the whole case archive (embedded classics plus every .m under data/matpower/). bench
bench --estimate Times the WLS estimator per case per step backend (dense versus sparse, forced through the sparse threshold) on a fixed-seed synthetic set; sampling and the truth solve sit outside the timed region. bench --estimate
bench --perf The focused before/after yardstick for the performance programme: single-threaded, warmed once, median of N runs, with managed allocations per run on the measuring thread. bench --perf
gpucheck Fail-fast GPU preflight: reports CPU, ROCm, OpenCL and CUDA availability and runs one tiny case9 solve (dense and sparse) on each present backend, flushing every step so a crash names the failing call. gpucheck
simdcheck Report the CPU's vector capabilities and the active tier (Avx512, Avx256, Sse128 or Scalar, with the number of doubles per vector step) that the dense-LU, normal-equations and covariance kernels dispatch to at run time. simdcheck
batchsolve Solve N same-sized MxM dense systems in one batched dispatch on the selected backend (the GPU batched Gaussian-elimination kernel on a CUDA or OpenCL device, else a parallel CPU loop over the reference LU; ROCm uses the CPU loop),... batchsolve
audit Verify a tamper-evident audit log (gridsim-audit/1, technical ch. 31): recompute the hash chain line by line. audit
compliance Print this build's compliance attestation and exit 0 when the build is compliant, 1 when it is not. compliance
ref Electrical references: a number written as electrical words that can be read aloud and typed back, one word per byte from a fixed list of 256 (units, pioneers, materials, physics, signals and more; no switching, safety, phase, colour,... ref

Generated from GridSim v2.1.073-RC-4 (commit 7c9a3409cc4decfd253567e423bf6f53bacb5390) · Source: tools/wiki/pages/CLI-quick-reference.md