Get started

Solve your first network with one command.

Download a self-contained build, run one command and compare the answer with a tool you trust. Licences are free today: ask by email.

Download

Ready-built for Windows, Linux and macOS.

The current public release is RC-4 (2.1.073). Every build is self-contained and carries the .NET 10 runtime, so there is nothing else to install.

RC-5 is the next release.

Open the releases page
On the release page
WhatPlatformFile
Command line tool (gridsim)Windows x64gridsim-<version>-win-x64.zip
Command line toolLinux x64gridsim-<version>-linux-x64.tar.gz
Command line toolmacOS arm64 (Apple silicon)gridsim-<version>-osx-arm64.tar.gz
Desktop app (Avalonia)Windows x64, Linux x64gridsim-app-<version>-win-x64.zip, gridsim-app-<version>-linux-x64.tar.gz
Desktop app (WPF)Windows x64gridsim-wpf-<version>-win-x64.zip
SBOMs and checksumsAnyCycloneDX *.sbom.json, SHA256SUMS.txt

Check every download against SHA256SUMS.txt. The release carries the platform downloads above, a CycloneDX SBOM for each, and SHA256SUMS.txt; the user manual, chapter 1, says how to check them.

First run

One command. One solved network.

Unpack the build and solve the IEEE 9-bus case. Newton-Raphson converges in four iterations to a mismatch of 1.65e-14 per unit.

Every verb answers --help with its usage, flags, defaults and exit codes. Then try:

  • gridsim case118 --once: any built-in case, or any MATPOWER file, the same way
  • gridsim --dir data/gb-full --once: the full GB transmission model, 3,539 buses
  • gridsim crossval case14: re-solve the case independently in pandapower
  • gridsim replay-event gb-2019-08-09: replay the 9 August 2019 GB disturbance
  • gridsim iec60909 case9 --bus 5: an IEC 60909 short-circuit duty study
Full quick startUser manual
$ gridsim case9 --once
GridSim  -  IEEE 9-bus (WSCC)
9 buses  9 branches  3 generators  base 100 MVA  60 Hz
========================================================================
Converged (4 NR iters, 0 OLTC passes, max mismatch 1.65E-014 p.u.)
Generator output 0.32 GW  Demand 0.32 GW  Losses 4.6 MW  Inertia 7.5 GVAs

Bus  Name                            kV    Vm(pu)  Va(deg)    P(MW)   Q(MVAr)
------------------------------------------------------------------------------
  1                                 345   1.040     0.00      71.6      27.0
  2                                 345   1.025     9.28     163.0       6.7
  3                                 345   1.025     4.66      85.0     -10.9
  4                                 345   1.026    -2.22      -0.0       0.0
  5                                 345   1.013    -3.69     -90.0     -30.0
  6                                 345   1.032     1.97       0.0      -0.0
  7                                 345   1.016     0.73    -100.0     -35.0
  8                                 345   1.026     3.72       0.0       0.0
  9                                 345   0.996    -3.99    -125.0     -50.0

Requirements

A laptop is enough.

Run

Operating system

Windows 10 or 11, 64-bit. x64 Linux with glibc 2.27 or later, such as Ubuntu 18.04, Debian 10 or RHEL 8 and newer. macOS on Apple silicon for the command line tool. No .NET install needed.

Size

Memory and CPU

8 GB of RAM runs every bundled case up to the 3,539-bus GB model; 16 GB holds every case GridSim ships. A 64-bit x86 processor, or Apple silicon on macOS; 8 cores with AVX2 or AVX-512 is recommended. A GPU is optional.

Build

From source

Install the .NET 10 SDK, then dotnet build GridSim.slnx -c Release. The build is warning-free by contract, and dotnet test runs the full suite.

Evaluation route

Research & academia

A declared fixture and a question that can be checked.

  1. Choose a model and record measured, inferred and assumed parameters.
  2. Define the independent reference, acceptance threshold and step-refinement checks.
  3. Distinguish numerical agreement from physical validation in the resulting paper or report.
See the research work

Evaluation route

.NET developers & integration teams

Evaluate a representative workload through the shared core.

  1. Review GridSim.Core and the documented architecture before selecting an integration boundary.
  2. Check lifecycle, concurrency, error handling and interface coverage on a case you can verify.
  3. Review the licence for incorporation, distribution and your intended use.
Inspect the architecture

Evaluation route

Technical evaluators

A matched comparison with visible eligibility conditions.

  1. Fix input identity, controls, tolerances, warm-up and timing boundaries.
  2. Record refusals and residual failures alongside successful cases.
  3. Inspect end-to-end work as well as the solve interval that a benchmark measures.
Read the benchmark method

Licence

Free to use today. Ask by email.

GridSim is source-available, not open source. The code is public on GitHub, and a licence governs its use.

Request a licence

Licences are issued free of charge today, for every tier, and there is no present intention to charge. Anyone who asks receives a Network Operator licence, which has no restrictions. Send the request to mark@gridsimdigitaltwin.co.uk.

Licensing is measured on buses and nothing else, and bundled networks never count toward a limit. GridSim ships with a licence mechanism so that the terms can be applied if that is ever needed, for example to support its development. Free licences today are not a promise that they will always be free.

Licence terms
UseBus limit
Personal, non-commercial1,500
Academic research and teaching1,500, larger on request; attribution required in publications
Commercial Code LicenceNone
Commercial Deployment LicenceNone
Network Operator (TSO, ESO, DNO)None; site-wide, subject to regulatory approval

These tiers are the licence mechanism, kept for future use. Today every licence is free on request: mark@gridsimdigitaltwin.co.uk.

The licence covers the software. Support, custom work or other commitments on your terms need a separate agreement.

Licence summary

Security

Report vulnerabilities privately.

Do not open a public issue, pull request or discussion for a vulnerability. Use GitHub private vulnerability reporting from the repository's Security tab, or email mark@gridsimdigitaltwin.co.uk.

Include the GridSim version (gridsim --version), the operating system, the steps or input that show the problem and what an attacker could do with it.

Report a vulnerabilityRead SECURITY.md
  1. Scored objectively

    Every report is assessed with CVSS v4.0 and v3.1 base scores, recorded in the security advisory with the reasoning.

  2. 48-hour target

    A base score of 7.0 or above is targeted for remediation within 48 hours: a fixed release and the published advisory.

  3. Fixed with a test

    Each fix ships with a test that reproduces the vulnerability and a Security entry in the CHANGELOG naming the advisory.

  4. Notified through GitHub

    Watch the repository for Releases and Discussions to be told when a fixed release is out. The latest release receives security fixes.

Tell us what you find

Run it against a case you trust.

Results, comparisons with other tools and bug reports are all wanted, agreement or not.

Send results or a bug report