GridSim documentation
The GridSim manuals and CLI reference, rendered from the repository at v2.1.073-RC-4.
Overview
User manual
- GridSim user manual
- 1. Getting started
- 2. Loading networks
- 3. Configuration
- 4. Licensing and activation
- 5. Running power flows
- 6. OPF, CPF, taps, distribution factors and losses
- 7. Three-phase distribution feeders
- 8. The desktop app
- 9. The web app and REST/WebSocket API
- 10. Analysis views
- 11. Contingency analysis
- 12. Faults, short circuit and protection grading
- 13. Battery storage studies
- 14. Frequency studies
- 15. RMS, modal and impedance stability
- 16. Electromagnetic transients (EMT)
- 17. Harmonic studies
- 18. Replaying recorded events
- 19. CLI reference
- 20. Counterfactuals
- 21. State estimation
- 22. Estimating GB history
- 23. Replaying estimated states
- 24. The GDA bridge
- 25. Interposing live telemetry
- 26. Audit log, deployment and assurance
- 27. Validation tools
- 28. Benchmarking and GPU
- 29. Extending GridSim
- 30. Troubleshooting
- 31. Exports and formats
- 33. The case editor
- 34. Time series and hosting capacity
- 35. Scripting
Technical manual
- GridSim technical manual
- 1. Architecture
- 2. Data model and per-unit conventions
- 3. Power flow
- 4. Sparse and GPU numerics
- 5. Frequency dynamics
- 6. State estimation
- 7. The evidence engine
- 8. Provenance and invariants
- 9. GDA integration
- 10. File and wire formats
- 11. Validation
- 12. Glossary
- 13. Asset-dynamics data grounding
- 14. Cascade validation and blind prediction
- 15. Protections
- 16. Physics conformance and the constrained estimator
- 17. Protection assessment (a passive relay overlay)
- 18. Real-time, distribution and dynamic estimation
- 19. Harmonics
- 20. The RTU/SCADA interposer
- 21. Electromagnetic transient (EMT) simulation
- 22. Licensing: key format and trust model
- 23. Contingency and security analysis (N-k)
- 24. Standard dynamic-model library
- 25. IEC 60909 short-circuit duty study
- 26. Overcurrent coordination (IDMT grading)
- 27. Battery energy storage
- 28. The v2 JSON schema
- 29. OPF, CPF, taps, distribution factors and loss allocation
- 30. Small-signal and impedance stability
- 31. Audit log and diagnostics
- 32. CIM/CGMES import and export
- 33. C37.118 synchrophasor ingest
- 34. Web host, REST/WebSocket, SSO and sessions
- 35. Deployment and security
- 36. Known limitations and design decisions
- 37. Quasi-static time series and hosting capacity
- 38. Deterministic mathematics
- IEEE C37.118.2 Synchrophasor Ingest + Phasor Data Concentrator - Technical Design
- Case editor design (GridSim.SchemaEditor)
- CIM / IEC 61970 (CGMES) network + measurement exchange
- Design: EMT time-domain solver (Dommel companion model)
- Robust GM estimation: leverage down-weighting, Schweppe-Huber, high-breakdown LTS/LMS, and HTI
- Unbalanced three-phase distribution state estimation (DSSE)
CLI
Generated from GridSim v2.1.073-RC-4 (commit 7c9a3409cc4decfd253567e423bf6f53bacb5390)